@article { author = {naeiji, esfandiyar and heydarian, hossein and ghanavati, hossein and javadiyan, behzad}, title = {power capacity Calculation for municipal waste biogas power plant (case study of Amol landfill)}, journal = {New Science and Technology}, volume = {1}, number = {2}, pages = {68-73}, year = {2019}, publisher = {}, issn = {2783-1094}, eissn = {2783-1094}, doi = {}, abstract = {Municipal solid waste is a main pollution source of water, air and soil. Municipal solid Waste management is one of the main problems of urban management, but in recent years, due to the nature of each type of waste such as decomposable organic matter and recyclable waste and rejected waste, methods have been developed to manage this waste worldwide. The main part of MSW in Iran is high-moisture degradable organic waste, which, along with its low calorific value and low potential for incineration, can be used in biological processes such as biogas production to stabilize and generate energy. In this study, a laboratory work to measure the potential for biogas production in digestion in Hansen method was compared with the potential for biogas production from the landfill according to the computational method and it was observed that after 5 years the potential for biogas energy production in digestion is 5 times that of the landfill}, keywords = {“MSW”,“biogas”,“digester”,“landfill”,“landGem”}, title_fa = {تعیین توان تولیدی نیروگاه بیوگاز سوز پسماند شهری (مطالعه موردی محل دفن آمل)}, abstract_fa = {پسماند شهری از منابع آلاینده منابع آب، هوا و خاک به شمار می‌رود. مدیریت این دسته پسماندها از مشکلات اصلی مدیریت شهری بوده اما در سالهای اخیر با توجه به ماهیت هر نوع پسماند اعم از قسمت های آلی تجزیه پذیر و قسمت های ریجکتی، روش هایی به منظور مدیریت و مهندسی این پسماندها در سطح جهان توسعه یافته اند. قسمت عمده پسماند شهر در ایران را پسماندهای آلی تجزیه پذیر با رطوبت بالا تشکیل می‌دهند که در کنار ارزش حرارتی پایین و پتانسیل ضعیف به منظور زباله سوزی، در فرآیندهای بیولوژیکی مثل تولید بیوگاز امکان مدیریت تثبیت و تولید انرژی را دارند. در این تحقیق با یک کار آزمایشگاهی به منظور پتانسیل سنجی تولید بیوگاز در هاضم به کمک استفاده از روش هانسن با پتانسیل تولید بیوگاز از محل دفن طبق روش محاسباتی مورد مقایسه قرار گرفته و مشاهده شد بعد از 5 سال پتانسیل تولید انرژی بیوگاز در هاضم 5 برابر محل دفن می‌باشد.}, keywords_fa = {"پسمتند شهری","بیوگاز" "هاضم","محل دفن" "لندجم"}, url = {https://www.jsat.ir/article_107425.html}, eprint = {https://www.jsat.ir/article_107425_6f998d98818ad3a7423c15fc48b783eb.pdf} } @article { author = {Aghabalaei, Vahid and mardani, shima and tabeshnia, mahla}, title = {Review of conventional and modern methods for nitrate removal from dirinking water in full scale}, journal = {New Science and Technology}, volume = {1}, number = {2}, pages = {74-84}, year = {2019}, publisher = {}, issn = {2783-1094}, eissn = {2783-1094}, doi = {}, abstract = {High cocentraion of nitrate in drinking water is one of the serious issue in the worlwide. Increasing nitrate concentration over 45 mg.L-1 will be caused Methemoglobinemi disease or Blue Baby Syndrome in child, forming carcinogenic compounds such as Nitrosamine and Nitrosamide Due to go up therisk of various cancers. Also eutrophication in receiving water will be happened by inhancing nitrogen compounds besides phosphore compounds into surface water. As a result of that is abundance of aquatic plants, algae growing, lack of soluble oxygen and aquatic death. Conventional processes in water treatments are not effective in nitrate removal. Nitrate management methods are included treatment and non treatment options. Asmuch as the water resources has limited, the importance of treatment methods rises day to day. In recent years, selecting the suitable method for nitrate removal is in dirinking water has important for the sustainability of the treatment system, economic efficiency and environmental friendl y further more many researches was done for improving and modifying conventional systems that some of them have been installed in full scale. This paper will be considered the experinces of other countries and the environmental and economic challenges because of using conventional methods, and technical and economical comparision will be done between conventional and modified methods in nitrate removal from dirinking water.}, keywords = {"Nitrate","dirinking water","technical and economical comparition","nitrate removal and treatment methods"}, title_fa = {مروری بر روش‌های متعارف و نوین حذف نیترات از آب آشامیدنی در مقیاس کامل}, abstract_fa = {آلودگی آب با غلظت‌های بالای نیترات مشکل جهانی است. افزایش غلظت نیترات بیش از 45 میلی‌گرم در لیتر، موجب بیماری متهموگلوبین، یا سندرم کودک کبود در کودکان و ایجاد ترکیبات سرطان‌زای نیتروزآمین و نیتروزآمید و افزایش احتمال ابتلا به سرطان‌های مختلف خواهد شد. همچنین افزایش ورود ترکیبات نیتروژنی در کنار ترکیبات فسفردار به منابع آب‌های سطحی، باعث ایجاد پدیده سرشاری غذایی در آب‌های پذیرنده شده و نتیجه آن، فراوانی گیاهان آبی و رشد جلبک‌ها، تهی‌شدن اکسیژن محلول و مرگ‌ آبزیان است. فرآیندهای متعارف تصفیه‌خانه‌های آب در حذف نیترات موثر نیستند. روش‌های مدیریت نیترات، گزینه‌های تصفیه‌ای و غیرتصفیه‌ای می‌باشند که با توجه به محدودیت منابع آبی اهمیت روش‌های تصفیه‌ای روز به روز بیشتر می‌گردد. در سال‌های اخیر، انتخاب روش مناسب حذف نیترات از آب آشامیدنی از نظر پایداری سیستم تصفیه، صرفه اقتصادی و دوستدار بودن محیط زیست بسیار حائز اهمیت بوده و تحقیقات زیادی جهت بهبود و اصلاح سیستم‌های متعارف انجام و بسیاری از آن‌ها در مقیاس صنعتی نصب شده‌اند. این مقاله ضمن بررسی برخی تجربیات سایر کشورها و چالش‌های زیست محیطی و اقتصادی مشاهده شده ناشی از استفاده از روش های متعارف، به مقایسه فنی و اقتصادی روش‌های متعارف و اصلاح شده حذف نیترات از آب آشامیدنی خواهد پرداخت.}, keywords_fa = {"نیترات","آب آشامیدنی","مقایسه فنی و اقتصادی","روش های حذف و تصفیه نیترات"}, url = {https://www.jsat.ir/article_107467.html}, eprint = {https://www.jsat.ir/article_107467_29256767103ba044357774aba729a553.pdf} } @article { author = {Jafari, Jafari and Seidabadi, Leila and Shakouri, Mahdi}, title = {The study for the application of photovoltaic modules and organic waste system for an under-construction hypermarket}, journal = {New Science and Technology}, volume = {1}, number = {2}, pages = {85-90}, year = {2019}, publisher = {}, issn = {2783-1094}, eissn = {2783-1094}, doi = {}, abstract = {In this study, the application of renewable energy and the use of organic waste for two escalators of a hypermarket has been discussed with energy efficiency perspectives. The mentioned escalators will be installed in a hypermarket in Karaj. The store's waste can also be used to extract thermal or electrical energy. At first, it has been evaluated if the required electrical energy for the electric motor of the escalator can be delivered through photovoltaic panels. The analysis results showed that the required energy for two desired escalators is equal to 3196 kWh on a daily basis. Then, using organic wastes has been investigated by the anesthetic digester mixing of biogas with a volume of 34 cubic meters. The results of this study illustrate that using a photovoltaic panel to supply the required power of the store's escalator is not cost-effective, while application of a biogas digester for extracting the energy from organic waste is not only useful however also can prevent environmental pollution.}, keywords = {“Photovoltaic panel”,“Anaerobic digestion”,“Energy extraction”,“biogas”}, title_fa = {مطالعه کاربرد سیستم فتوولتائیک و استفاده از سیستم پسماندهای آلی برای فروشگاه بزرگ در حال تاسیس}, abstract_fa = {در این تحقیق، طرح فنی بهره‌برداری از انرژی‌های تجدیدپذیر برای دو دستگاه پله برقی به منظور تسهیل رفت و آمد مشتریان و همچنین استفاده از پسماندهای آشپزخانه‌ای و تبدیل آن ها به انرژی مفید بررسی شده است. پله برقی مذکور در یک فروشگاه بزرگ شهر کرج نصب خواهد شد. همچنین از پسماندهای این فروشگاه برای استحصال انرژی حرارتی یا الکتریکی می‌توان بهره برد. در ابتدا، انرژی الکتریکی مورد نیاز برای الکتروموتور پله برقی و طراحی پنل‌های فتوولتاییک انجام شده است. نتایج طراحی این بخش نشان می‌دهد که انرژی مورد نیاز برای تامین برق دو پله برقی مورد نظر برابر با 3196 کیلووات ساعت در روز است. در ادامه با استفاده از پسماندهای فسادپذیر شامل پسماندهای آشپزخانه‌ای یک هاضم بی‌هوازی اختلاط کامل بیوگاز با حجم 34 متر مکعب طراحی شده است. نتایج تحلیل و بررسی‌های انجام شده در این تحقیق نشان می‌دهد که استفاده از پنل فتوولتاییک برای تامین برق پله برقی فروشگاه حاضر مقرون به صرفه نبوده درحالی‌که می‌توان با طراحی یک هاضم بیوگاز، از پسماندهای فسادپذیر انرژی استحصال و از آلودگی محیط نیز جلوگیری کرد.}, keywords_fa = {"پنل فتوولتاییک","هاضم بی‌هوازی","استحصال انرژی","بیوگاز"}, url = {https://www.jsat.ir/article_107468.html}, eprint = {https://www.jsat.ir/article_107468_c80e08fdc629340a77bc80d3a140678b.pdf} } @article { author = {Borhani, Faezeh and Zahed, Fatemeh and Noorpoor, Alireza}, title = {Modeling and evaluating the contribution of NOX and CO pollutants emitted in the insulation Bituminous units (Isogam) exhaust flue gas on the around area (Case study: Delijan City)}, journal = {New Science and Technology}, volume = {1}, number = {2}, pages = {91-100}, year = {2019}, publisher = {}, issn = {2783-1094}, eissn = {2783-1094}, doi = {}, abstract = {. For this purpose, the chimney outlet parameters of one unit are measured by gas analyzer KIMO, KIGAZ300.Then, using climate variables like temperature, humidity, wind speed or direction with the daily Delijan 2015 weather station and emission source characteristics including the chimney height, speed and exhaust gas temperature, the rate of emission, etc., its distribution is modeled by AERMOD software. The model is designed to estimate the discharge rate from adjacent sources (less than 50 km). In order to determine and evaluate the unit's share of total emissions in the sample-studied materials in summer the 4-polluting source of all the chimneys were measured. Results of air pollution dispersion modeling shows that the highest concentration of Carbon monoxide and nitrogen oxide are 0.19348 and 0.14003μg/m3 on hourly average and occurred in the eastern part of the North. Evaluating the results of modeling and measuring carbon monoxide emissions in several points of the city, CO and NOX percent (as environmental pollutants) are determined 0.26 and 0.14 respectively in urban air.}, keywords = {Isogam Bituminous unit”,“air pollutants emissions”,“Dispersion”,“AERMOD model”}, title_fa = {مدل سازی و ارزیابی سهم انتشار آلاینده های NOX و CO خروجی از دودکش یک کارخانه تولید ایزوگام روی منطقه اطراف ( مطالعه موردی: دلیجان)}, abstract_fa = {به منظور تعیین سهم کارخانه ایزوگام مورد مطالعه از کل منابع آلاینده، ابتدا نمونه برداری در فصل پاییز از 4 منبع نقطه ای که خروجی دودکش های یک کارخانه پخت ایزوگام می باشند برای دو آلاینده منوکسید کربن و اکسیدهای ازت بعمل آمد پس از اعمال مقادیر اندازه گیری شده خروجی دودکش ها در مدل AERMOD و مدلسازی انتشار آلاینده های خروجی دودکش ها در منطقه اطراف، میزان نشر حاصل از مدلسازی در چهار نقطه معینی از محوطه اطراف کارخانه (چهارگوشه کارخانه) مشخص گردید. مقایسه نتایج حاصل از مدل سازی پراکنش آلودگی با مقادیر اندازه گیری شده در همان نقاط نشان داد غلظت آلاینده ها ناشی از غلظت آلاینده منوکسید کربن به مقدار 19348/0 میکروگرم بر مترمکعب و ناشی از آلاینده اکسید ازت 14003/0 میکروگرم بر مترمکعب، در متوسط زمانی یک ساعته می باشد. با مقایسه نتایج حاصل از مدل سازی انتشار و اندازه گیری میدانی میزان آلاینده منوکسید کربن و اکسیدهای ازت در هوای محیطی چهار نقطه مشخص می شود سهم آلاینده منوکسید کربن و اکسیدهای ازت ناشی از یک واحد تولید ایزوگام در هوای شهر به ترتیب برابر 26/0 و 14/0 درصد می باشد.}, keywords_fa = {"کارخانه ایزوگام","پراکنش","انتشار آلاینده","مدل AERMOD "}, url = {https://www.jsat.ir/article_107477.html}, eprint = {https://www.jsat.ir/article_107477_43d561394cc5f126976151c77bf04552.pdf} } @article { author = {mardani, shima and Aghabalaei, Vahid and Tabeshnia, Mahla}, title = {The importance of selecting sludge treatment process in reducing the energy consumption of wastewater treatment plants}, journal = {New Science and Technology}, volume = {1}, number = {2}, pages = {101-106}, year = {2019}, publisher = {}, issn = {2783-1094}, eissn = {2783-1094}, doi = {}, abstract = {The link between water and enragy is one of the key elements for the sustainable development of human societies and wastewater treatment plants are an example of the intraction of this link. Generally, wastewater treatment consists of two parts, liquid, and sludge treatment and one of most complications and costly parts of treatment plants belongs to management and treatment of sludge that up to 60% of costs of capital and operation costs of each wastewater treatment plants can allocate to that. Considering the importance of reducing energy consumption in wastewater treatment plants as an environmental and economic point of view, some attempts and investigations have done to construct and modify wastewater plants worldwide in order to the self-sufficiency of energy supply from influent recently year. Also, energy recovery and sludge management behind in large urban treatment plants have become more important in small and medium scale treatment units in the last decades while the variety of wastewater treatment plants have constructed with more than 20000 m3/d in capacity with along aerobic sludge digestion process in which energy has consumed more than same units in these years in Iran. This article analyses a process that is used in a wastewater treatment plant in Iran that its capacity is 80000m3/d and equipped by the MLE process and aerobic sludge digestion compare with anaerobic sludge digestion. Findings reveal the importance of choosing suitable sludge treatment process in the recovery and reduction of consumption energy.}, keywords = {" water and energy recovery "," wastewater treatment plants"," self-sufficiency of energy consumption ","sludge treatment system "}, title_fa = {اهمیت انتخاب فرآیند تصفیه بخش لجن در کاهش مصرف انرژی تصفیه‌خانه‌های فاضلاب}, abstract_fa = {پیوند آب و انرژی یکی از عنصرهای اصلی توسعه پایدار جوامع انسانی محسوب شده و تصفیه‌خانه‌های فاضلاب نمونه‌ای از تعامل و تاثیر متقابل این پیوند می‌باشند. تصفیه فاضلاب شامل دو بخش تصفیه مایع و لجن است. تصفیه و مدیریت لجن یکی از پیچیده‌ترین و هزینه‌برترین بخش‌های تصفیه‌خانه بوده و می‌تواند تا 60 درصد هزینه‌های سرمایه‌گذاری اولیه و بهره‌برداری یک تصفیه‌خانه فاضلاب را به خود اختصاص دهد. با توجه به اهمیت کاهش مصرف انرژی در تصفیه‌خانه‌های فاضلاب از نظر محیط زیستی و اقتصادی، در سال‌های اخیر تحقیقات و تلاش‌های زیادی در زمینه خودکفایی تامین انرژی از فاضلاب ورودی انجام شده و براساس این هدف تصفیه‌خانه-های فاضلاب متعددی در جهان احداث یا بهینه‌سازی شده‌اند. این در حالی است که در سال‌های اخیر در کشور، تصفیه‌خانه‌های فاضلاب متعددی با ظرفیت بیش از 20000 مترمکعب در روز با فرآیند هاضم هوازی لجن احداث و یا در حال ساخت می‌باشند که انرژی بسیار بالاتری نسبت به تصفیه‌خانه‌های مشابه مصرف می‌کنند. در این مقاله فرآیند مورد استفاده در برخی تصفیه‌خانه‌های فاضلاب به روش MLE همراه با هاضم هوازی در مقایسه با هاضم بی‌هوازی مورد تجزیه و تحلیل قرار گرفته است. نتایج این تحقیق نشان داد نوع و انتخاب فرآیند مناسب در بخش لجن در کاهش میزان انرژی مصرفی بسیار اهمیت دارد.}, keywords_fa = {" بازیابی منابع آبی و انرژی ","تصفیه خانه‌های فاضلاب"," خودکفایی انرژی مصرفی "," سیستم تصفیه لجن"}, url = {https://www.jsat.ir/article_107484.html}, eprint = {https://www.jsat.ir/article_107484_f3c64e4644d7e8f0e89a5a81bd4e005a.pdf} } @article { author = {Shakouri, Mahdi and Shekari, Nasim}, title = {Implementation of Energy Management System in a Petrochemical Plant Based on International Approaches}, journal = {New Science and Technology}, volume = {1}, number = {2}, pages = {107-112}, year = {2019}, publisher = {}, issn = {2783-1094}, eissn = {2783-1094}, doi = {}, abstract = {In this research, the implementation of energy management system within an industrial plant has been reviewed. The studied case is a petrochemical plant in Iran and the research team has investigated the impact of energy management system on the organizational energy performance improvement using international practices and approaches. In order to cover the aim of this study, the research team has provided a questionnaire considering seventeen essential criteria of the energy management system which was filled before and after implementation of the system in the studied case. The research team with the help of the company’s key personal have implemented energy management system between two periods of the evaluation and some important results from the actions are provided in this paper. According to the results, the annual energy performance of the company has improved by 4.1 percent in compare to the baseline. In addition, all seventeen criteria have led to the improved results after implementation of the energy management system.}, keywords = {“Energy Management System”,“Energy Performance Improvement”,“Energy saving”,“Energy Efficiency”,“Petrochemical Industry”}, title_fa = {پیاده سازی سیستم مدیریت انرژی در یک واحد پتروشیمی براساس رویکردهای بین المللی}, abstract_fa = {در این مقاله، پیاده سازی سیستم مدیریت انرژی در یک واحد صنعتی بررسی شده است. واحد صنعتی مورد مطالعه یک شرکت پتروشیمی در کشور ایران است و تیم تحقیق با استفاده از تجربیات و رویکردهای بین المللی اقدام به بررسی تاثیر سیستم مدیریت انرژی بر بهبود عملکرد انرژی سازمان داشته است. برای انجام این بررسی، پرسش نامه ای براساس هفده معیار کلیدی سیستم مدیریت انرژی تنظیم شده و این پرسش نامه در دو بازه زمانی پیش و پس از پیاده سازی سیستم مدیریت انرژی در واحد صنعتی تکمیل شده است. در فاصله بین دو مرحله ارزیابی، تیم تحقیق به همراه کارکنان کلیدی واحد صنعتی اقدام به پیاده سازی سیستم مدیریت انرژی نمود و نتایج برخی اقدامات کلیدی مرتبط در این تحقیق ارائه شده است. براساس نتایج این اقدامات، عملکرد انرژی سالانه سازمان به میزان 4.1 درصد در مقایسه با خط مبنا بهبود یافته است. همچنین مقایسه نتایج ارزیابی پس از پیاده‌سازی سیستم مدیریت انرژی نشان می دهد که امتیاز تمام هفده معیار در واحد صنعتی مورد مطالعه بهبود داشته است.}, keywords_fa = {"سیستم مدیریت انرژی","بهبود عملکرد انرژی","صرفه جویی انرژی","بهره وری انرژی","صنعت پتروشیمی"}, url = {https://www.jsat.ir/article_107486.html}, eprint = {https://www.jsat.ir/article_107486_bf6bd3e4145f984436afc5bda303d339.pdf} }